Gregel, Jorg Andreas (1995) A Proton Detector for Medium Energy Physics. MSc(R) thesis, University of Glasgow.
Full text available as:
PDF
Download (1MB) |
Abstract
This thesis is concerned with a proton detector matrix used in a measurement of the 12C(gamma,Pgamma')1B reaction. The matrix consists of 20 CsI(Tl) crystals, each of which is read out by a photodiode. Chapter 1 gives an introduction into the physics of the experiment and explains the aim and execution of this experiment. Chapter 2 is a description of the detector composition including the electronics. Chapter 3 contains measurements which have been made in order to obtain optimum energy resolution and uniform light collection efficiency for the detector. Chapter 4 describes some Monte Carlo models. These models are investigations into the light collection efficiencies for different crystal and diode sizes and the proton detection characteristics. Chapter 5 gives a description of the setup used in the 12C(gamma,Pgamma')1B experiment. It also presents some preliminary results of this experiment.
Item Type: | Thesis (MSc(R)) |
---|---|
Qualification Level: | Masters |
Additional Information: | Adviser: John Annand |
Keywords: | High energy physics, Nuclear physics and radiation |
Date of Award: | 1995 |
Depositing User: | Enlighten Team |
Unique ID: | glathesis:1995-74571 |
Copyright: | Copyright of this thesis is held by the author. |
Date Deposited: | 27 Sep 2019 17:44 |
Last Modified: | 27 Sep 2019 17:44 |
URI: | https://theses.gla.ac.uk/id/eprint/74571 |