Design and implementation of miniaturised capsule for autofluorescence detection with possible application to the bowel disease

Al-Rawhani, Mohammed Abdul Wahab (2012) Design and implementation of miniaturised capsule for autofluorescence detection with possible application to the bowel disease. PhD thesis, University of Glasgow.

Full text available as:
[thumbnail of 2012Al-RawhaniPhD.pdf] PDF
Download (6MB)
Printed Thesis Information: https://eleanor.lib.gla.ac.uk/record=b2939592

Abstract

Early signs of intestinal cancer may be detected through variations in tissue autofluorescence (AF), however current endoscope-based AF systems are unable to inspect the small intestine. This thesis describes the design, fabrication, implantation, testing and packaging of a wireless pill capable of detecting the autofluorescence from cancerous cells, and able to reach parts of the gastrointestinal tract that are inaccessible to endoscopes. The pill exploits the fact that there is a significant difference in the intensity of autofluorescence emitted by normal and cancerous tissues when excited by a blue or ultra violet light source. The intensity differences are detected using very sensitive light detectors. The pill has been developed in two stages. The first stage starts with using an off-chip multi-pixel photon counter (MPPC) device as a light detector. In the second stage, the light detector is integrated into an application specific integrated circuit (ASIC). The pill comprises of an ASIC, optical filters, an information processing unit and a radio transmission unit, to transmit acquired data to an external base station. Two ASICs have been fabricated, the first stage of this work involved implementing an ASIC that contains two main blocks; the first block is capable of providing a variable DC voltage more than 72 V from a 3 V input to bias the MPPC device. The second main block is a front-end consisting of a high speed transimpedance amplifier (TIA) and voltage amplifiers to capture the very small current pulses produced by the MPPC. The second ASIC contains a high voltage charge pump up to (37.9 V) integrated with a single photon avalanche detector (SPAD). The charge pump is used to bias the SPAD above its breakdown voltage and therefore operate the device in Geiger mode. The SPAD was designed to operate in the visible region where its photon detection efficiency (PDE) peaks at 465 nm, which is near to human tissues autofluorescence peaking region (520±10 nm). The use of the ultra low light detector to detect the autofluorescence permits a lower excitation light intensity and therefore lower overall power consumption. The two ASICs were fabricated using a commercial triple-well high-voltage CMOS process. The complete device operates at 3V and draws an average of 7.1mA, enabling up to 23 hours of continuous operation from two 165mAh SR44 batteries.

Item Type: Thesis (PhD)
Qualification Level: Doctoral
Keywords: Autofluorescence endoscopy, endoscopic capsule, SPAD, non-invasive diagnosis.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering
Colleges/Schools: College of Science and Engineering > School of Engineering
Supervisor's Name: Cumming, Prof. David R.S.
Date of Award: 2012
Depositing User: Mr. Mohammed Abdulwahab Al-Rawhani
Unique ID: glathesis:2012-3469
Copyright: Copyright of this thesis is held by the author.
Date Deposited: 31 Jul 2012
Last Modified: 10 Dec 2012 14:07
URI: https://theses.gla.ac.uk/id/eprint/3469

Actions (login required)

View Item View Item

Downloads

Downloads per month over past year